User Manual

Table Of Contents
Installing the Systems Insight Display power module
Prerequisites
Before installing this option, be sure you have the following:
The components included with the hardware option kit
T-10 Torx screwdriver
Procedure
1. Observe the following alerts:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal
system components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before
beginning any installation procedure. Improper grounding can cause electrostatic discharge.
2. Back up all server data.
3. Power down the server (Powering down the server on page 30).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack (Extend the server from the rack on page 30).
b. Remove the server from the rack (Remove the server from the rack on page 31).
6. Remove the access panel (Remove the access panel on page 31).
7. Disconnect the Power/UID/USB cable from the front power button/USB 3.0 on the system board.
Hardware options installation 113