IMPORTANT: To support NVDIMMs, the HPE Smart Storage Battery must be installed.
A single 96W battery can support up to 24 devices.
After the battery is installed, it might take up to two hours to charge. Controller features requiring backup
power are not re-enabled until the battery is capable of supporting the backup power.
This server supports the 96W HPE Smart Storage Battery with the 145mm cable.
HPE Smart Storage Hybrid Capacitor
The HPE Smart Storage Hybrid Capacitor supports the following devices:
HPE Smart Storage SR controllers
HPE Smart Storage MR controllers
IMPORTANT: NVDIMMs are only supported by the HPE Smart Storage Battery.
The capacitor pack can support up to three devices or 600 joules.
This server supports the HPE Smart Storage Hybrid Capacitor with the 145mm cable.
Before installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum
firmware requirements to support the capacitor pack.
IMPORTANT: If the system BIOS or controller firmware is older than the minimum recommended
firmware versions, the capacitor pack will only support one device.
The capacitor pack is fully charged after the system boots.
Minimum firmware versions
Product Minimum firmware version
HPE ProLiant DL360 Gen10 Server system ROM
2.00
HPE Smart Array SR controllers 1.90
HPE Smart Array MR controllers 24.23.0-0041
Energy pack option configurations
In the HPE ProLiant DL360 Gen10 Server , an energy pack can be installed in two different orientations,
depending on configuration:
Installing an energy pack in 8 SFF and 4 LFF configurations on page 128
Installing an energy pack in the 10 SFF SAS/SATA/NVMe Combo backplane configuration on page
126
Hardware options installation 125