a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Do one of the following:
a. Extend the server from the rack (Extend the server from the rack on page 30).
b. Remove the server from the rack (Remove the server from the rack on page 31).
4. Remove the access panel (Remove the access panel on page 31).
5. Locate any NVDIMMs already installed in the server.
6. Verify that all LEDs on any installed NVDIMMs are off.
7. Install the NVDIMM.
8. Install and connect the HPE Smart Storage Battery, if it is not already installed.
Installing an energy pack in 8 SFF and 4 LFF configurations on page 128
Installing an energy pack in the 10 SFF SAS/SATA/NVMe Combo backplane configuration on
page 126
9. Install any components removed to access the DIMM slots and the HPE Smart Storage Battery.
10. Install the access panel.
11. Slide or install the server into the rack.
12. If removed, reconnect all power cables.
13. Power up the server.
14. If required, sanitize the NVDIMM-Ns. For more information, see NVDIMM sanitization on page 53.
Configuring the server for NVDIMMs
After installing NVDIMMs, configure the server for NVDIMMs. For information on configuring settings for
NVDIMMs, see the HPE 16GB NVDIMM User Guide on the Hewlett Packard Enterprise website (
http://
www.hpe.com/info/nvdimm-docs).
52 Hardware options installation