HPE ProLiant DL360 Gen10 Server
Technical Specifications
Page
66
Maximum Peak Power
• For 1600W Power Supply: 1600W (at 240 VAC), 1600W (at 240 VDC) for China only
• For 800W (Titanium) Power Supply: 800W (at 200 VAC), 800W (at 240 VAC), 800W (at 240 VDC) for China only
• For 800W (Platinum) Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VDC) input for China only
• For 800W (Universal) Power Supply: 800W (at 200 VAC), 800W (at 277 VAC)
• For 800W (-48VDC) Power Supply: 800W (at -40 Vdc), 800W (at -72Vdc)
•
For 500W (Platinum) Power Supply: 500W (at 100 VAC), 500W (at 240 VAC), 500W (at 240 VDC) input for China only
System Inlet Temperature
Standard Operating Support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above sea
level
to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr (36°F/hr). The upper lim
it
and rate of change may be limited by the type and number of options installed.
System performance during standard operating support may be reduced if operating with a fan fault or above 30°C (86°F).
For approved hardware configurations, the supported s
ystem inlet range is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C
(95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above 900 m (2953 ft)
to a
maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the URL:
http://www.hpe.com/servers/ashrae
Extended Ambient Operating Support
For approved hardware configurations, the supported system inlet range is
extended to be: 40° to 45°C (104° to 113°F) at sea level
with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,
000
ft). The approved hardware configurations for this system are listed at the URL:http://www.hpe.com/servers/ashrae
System performance may be reduced if operating in the extended ambient operating range or with a fan fault.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Relative Humidity (non-condensing)
Operating
8% to 90% - Relative humidity (Rh), 28°C maximum wet bulb temperature, non-condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb temperature, non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude change
rate
is 457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).