CAUTION: Be sure to tighten each heatsink nut fully in the order indicated. Otherwise, boot
failure or intermittent shutdowns might occur.
c. Using a T-30 Torx screwdriver, tighten the nuts until they stop.
12. Install the fans.
13. Install the access panel.
14. Install the server into the rack.
15. Connect all peripheral cables to the server.
16. Connect each power cord to the server.
17. Connect each power cord to the power source.
18. Power up the server.
19. If removed, install the bezel.
The installation is complete.
Installing the Chassis Intrusion Detection switch
Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit.
Procedure
1. Back up all server data.
2. If installed, remove the bezel.
3. Power down the server.
4. Remove all power:
86 Hardware options installation