ProLiant DL180 Gen10 Server
Table Of Contents
QuickSpecs
HPE ProLiant DL180 Gen10 Server
Technical Specifications
Page 22
System Unit
Dimensions
8.73 x 44.54 x 63.47 cm 3.44 x 17.54 x 24.99 in
Weight (approximate)
13.0 kg
28.0 lb
Minimum: 8 SFF chassis with 1x SFF HDD and 7 HDD blanks, 2x Drive Bay
blanks, 1x processor including standard heatsink, 1x power supply (plus
blank), 1x Smart Array, 1x Riser installed, cables for the above)
Input Requirements
(per power supply)
Rated Line Voltage
100 to 120 VAC
200 to 240 VAC
BTU Rating
Maximum
For 500W Power Supply: 1979 BTU/hr (at 100 VAC), 1911 BTU/hr (at
200 VAC), 1965 BTU/hr (at 240 VAC) for China Only
Power Supply Output
(per power supply)
Rated Steady-State
Power
For 500W Power Supply: 500W (at 100 VAC), 500W (at 240 VAC), 500W
(at 240 VAC) input for China only
System Inlet Temperature
Standard Operating
Temperature
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C
per every 305 m (1.8°F per every 1000 ft) above sea level to a maximum
of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of
change is 20°C/hr (36°F/hr). The upper limit and rate of change m
ay be
limited by the type and number of options installed.
System performance during standard operating support may be reduced
if operating with a fan fault or above 30°C (86°F).
Extended Ambient
Operating Temperature
For approved hardware configurations, the supported system inlet range
is extended to be: 5° to 10°C (41° to 50°F) and 35° to 40°C (95° to 104°F)
at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per
every 574 ft) above 900 m (2953 ft) to a maximum of 3050 m (10,000
ft)
. The approved hardware configurations for this system are listed at the
URL:
http://www.hpe.com/servers/ashrae
For approved hardware configurations, the supported system inlet range
is extended to be: 40°
to 45°C (104° to 113°F) at sea level with an altitude
derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m
(2953 ft) to a maximum of 3050 m (10,000 ft). The approved hardware
configurations for this system are listed at the URL:
http://www.hpe.com/servers/ashrae
System performance may be reduced if operating in the extended ambient
operating range or with a fan fault.
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr
(36°F/hr).
Relative Humidity
Operating
8% to 90% - Relative humidity (Rh), 28°C maximum wet bulb temperature,
non-condensing.
(non-condensing)
Non-operating
5 to 95% relative humidity (Rh), 38.7°C (101.7°F) maximum wet bulb
temperature, non-condensing..
Altitude
Operating
3050 m (10,000 ft). This value may be limited by the type and number of
options installed. Maximum allowable altitude change rate is 457 m/min
(1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457
m/min (1500 ft/min).