Product Data Sheet / Brochure
Table Of Contents
QuickSpecs
HPE ProLiant DL380 Gen10 Plus Server
Configuration Information
Page 28
−
Redhat RHEL 7.2, RHEL 8.0, and later.
− SUSE SLES 12 SP2, SLES 15 GA and newer
− VMware vSphere 6.7, 6.7U1, 6.7U2, 6.7U3, 7.0U1 and newer
Factory Instructions and Server Settings
HPE SR100i Gen10 Plus FIO Software RAID
P28417-B21
Notes:
− The Legacy Mode Setting and HPE SR100i Gen10 Plus FIO SW CAN NOT be selected together.
− NVMe Trigger and SR100i (P28417-B21) cannot be selected together.
− SR100i (P28417-B21) and VROC SKUs (R7J57A/ R7J58A) CAN NOT be selected together.
− SR100i can support max 2 NVMe drives. To enable 2NVMe support with SR100i below conditions must
be met:
o Tertiary 2port Slimline Riser (P27093-B21) OR AROC to NVMe adapter (P14602-B21) must be
selected
o Or 2SFF x4Tri-Mode U.3 Kit (P26922-B21) OR 2SFF x4Tmode SbS U.3 Kit (P26924-B21) must be
selected
−
If NVMe support is enabled on SR100i then below NVMe drives cannot be selected. However if there are
any U.3 cage or U.2 NVMe Drive cage which are enabled to have NVMe drives then below drives can be
selected however quantities to be restricted only to these drive cages
− CM6 in drive description
− CD6 in drive description
− P4xxx in drive description
HPE 200GB Logical Size FIO Setting
436007-B21
Notes:This option is not required and is only selectable if a RAID level has been selected.
HPE RAID 0 Drive 1 FIO Setting
339777-B21
Notes:
- If Embedded SATA controller (with SR100i Setting (P28417-
B21)) is the primary controller, then RAID 0,
1, 5 are allowed.
- If E208i-a/E208i-p is the primary controller, then RAID 0, 1, 5 levels are allowed.
- If MR216i-a/MR216i-p is the primary controller, then RAID 0, 1 levels are allowed.
- If RAID is selected on NVMe drives without Tri Mode controllers then SR100i mode must selected, and
RAID 0, 1 levels are allowed.
HPE RAID 1 Drive 1 FIO Setting
339778-B21
Notes:
- If Embedded SATA controller (with SR100i Setting (P28417-
B21)) is the primary controller, then RAID 0,
1, 5 are allowed.
- If E208i-a/E208i-p is the primary controller, then RAID 0, 1, 5 levels are allowed.
- If MR216i-a/MR216i-p is the primary controller, then RAID 0, 1 levels are allowed.
- If RAID is selected on NVMe drives without Tri Mode controllers then SR100i mode must selected, and
RAID 0, 1 levels are allowed.
HPE RAID 5 Drive 1 FIO Setting
339779-B21
Notes:
- If Embedded SATA controller (with SR100i Setting (P28417-
B21)) is the primary controller, then RAID 0,
1, 5 are allowed.
- If E208i-a/E208i-p is the primary controller, then RAID 0, 1, 5 levels are allowed.
HPE Raid 5 w/SP Drive 1 FIO Setting
339780-B21
HPE RAID FIO Advanced Data Guarding Option
339781-B21