ProLiant DL380 Gen10 Plus Server
Table Of Contents
QuickSpecs
HPE ProLiant DL380 Gen10 Plus Server
Technical Specifications
Page 53
Power Supply Output
(per power supply)
Rated Steady-State Power
• For 1600W Power Supply: 1600W (at 240 VAC), 1600W (at 240 VDC) for China only
• For 800W (Titanium) Power Supply: 800W (at 200 VAC), 800W (at 240 VAC), 800W (at 240 VDC) for China only
• For 800W (Platinum) Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VDC) input for China only
• For 800W (Universal) Power Supply: 800W (at 200 VAC), 800W (at 277 VAC)
• For 800W (-48VDC) Power Supply: 800W (at -40 Vdc), 800W (at -72Vdc)
Maximum Peak Power
• For 1600W Power Supply: 1600W (at 240 VAC), 1600W (at 240 VDC) for China only
• For 800W (Titanium) Power Supply: 800W (at 200 VAC), 800W (at 240 VAC), 800W (at 240 VDC) for China only
• For 800W (Platinum) Power Supply: 800W (at 100 VAC), 800W (at 240 VAC), 800W (at 240 VDC) input for China only
• For 800W (Universal) Power Supply: 800W (at 200 VAC), 800W (at 277 VAC)
• For 800W (-48VDC) Power Supply: 800W (at -40 Vdc), 800W (at -72Vdc)
System Inlet Temperature
• Standard Operating Temperature
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above
sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 20°C/hr
(36°F/hr). The upper limit and rate of change may be limited by the type and number of options installed.
System performance during standard operating support may be reduced if operating with a fan fault or above 30°C (86°F).
• Extended Ambient Operating Temperature
For approved hardware configurations, the supported system inlet range is extended to be: 5° to 10°C (41° to 50°F) and
35° to 40°C (95° to 104°F) at sea level with an altitude derating of 1.0°C per every 175 m (1.8°F per every 574 ft) above
900 m (2953 ft) to a maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at
the URL: http://www.hpe.com/servers/ashrae
For approved hardware configurations, the supported system inlet range is extended to be: 40° to 45°C (104° to 113°F)
at sea level with an altitude derating of 1.0°C per every 125 m (1.8°F per every 410 ft) above 900 m (2953 ft) to a
maximum of 3050 m (10,000 ft). The approved hardware configurations for this system are listed at the URL:
http://www.hpe.com/servers/ashrae
System performance may be reduced if operating in the extended ambient operating range or with a fan fault.
• Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of change is 20°C/hr (36°F/hr).
Altitude
• Operating
3050 m (10,000 ft). This value may be limited by the type and number of options installed. Maximum allowable altitude
change rate is 457 m/min (1500 ft/min).
• Non-operating
9144 m (30,000 ft). Maximum allowable altitude change rate is 457 m/min (1500 ft/min).