User manual
VDPL300D_v2  HQPOWER™ 
4
7. DMX Mode 
The DMX mode allows you to control the unit through a universal DMX controller. Set DIP switch 10 
to ON to activate the DMX mode, set the DMX address using DIP switches 1 to 9. 
Detailed DMX Values per Channel 
Channel Function From To Description 
1 ~ 6  Clusters 
0 10 No function 
11 45 Red 
46 80 Green 
81 115 Blue 
116  150  Red – green 
151  185  Red – blue 
186  220  Green – blue 
221 255 RGB 
7 Strobe 
0 10 No function 
11 255 S>F strobe 
8 Auto speed 
0 10 No function 
11 24 Auto 1 
25 38 Auto 2 
39 52 Auto 3 
53 66 Auto 4 
67 80 Auto 5 
81 94 Auto 6 
95 108 Auto 7 
109 122 Auto 8 
123 136 Auto 9 
137 150 Auto 10 
151 164 Auto 11 
165 178 Auto 12 
179 192 Auto 13 
193 206 Auto 14 
207 220 Auto 15 
221 249 Auto 15 
251 255 Auto trigger 
DMX512 Connection 
Connect the provided XLR cable to the female 3-pin XLR output of your controller and the other side 
to the male 3-pin XLR input of the VDPL300D. Multiple VDPL300Ds can be linked through serial 
linking. The linking cable should be a two-core screened cable with XLR input and output connectors. 
DMX512 Chain with Termination 
A DMX terminator is recommended for installations where the DMX cable has 
to run a long distance or is in an electrically noisy environment (e.g. discos). 
The terminator prevents corruption of the digital control signal by electrical 
noise. The DMX terminator is simply an XLR plug with a 120Ω resistor 
between pins 2 and 3, which is then plugged into the XLR output socket of 
the last device in the chain. 
Please see illustrations. 
DMX512 Start Address 
All DMX-controlled devices need a digital start address so that the correct device responds to the 
signals. This start address is the channel number from which the device starts to “listen” to the DMX 
controller. Enter the correct number and read it from the display located on the base of the 
VDPL300D. 