HQ-INV2500/12 HQ-INV2500/12F HQ-INV2500/24 HQ-INV2500/24F 12V DC to 230V AC Soft Start Power Inverter 24V DC to 230V AC Soft Start Power Inverter 2500 WATT CONTINUOUS OUTPUT POWER MANUAL ENGLISH 021895
SAFETY PRECAUTIONS: To reduce risk of electric shock, this product should ONLY be opened by an authorized technician if service is required. Disconnect the product from mains and other equipment if a problem should ocure. Do not expose the product to water of moisture. WARRANTY: No guarantee or liability can be accepted for any changes and modifications of the product or damage caused due to incorrect use of this product. GENERAL: Designs and specifications are subject to change without a notice. 1.
2.INSTALLATION Mount the inverter horizontally or vertically on a flat surface. CAUTION! Make sure to following these rules when installing the inverter: 1. Make sure the inverter stays dry 2. The inverter should be installed in a cool place, ambient temperature between 0-25°C. 3. To avoid fire hazard and overheating, do not cover or obstruct the ventilation openings of the inverter. Regularly check the ventilation openings because these especially collect dust and dirt.
2.1.1. ON/OFF switch For turning the inverter on/off. 2.1.2. Remote ON/OFF jack Allows you to mount the inverter out of sight and turn ON or OFF with the included remote control 2.1.3. Battery voltage (VOLTS) indicator The battery voltage indicator displays the voltage at the input terminal of the inverter. 2.1.4. Battery current (AMPS) indicator The battery current indicator displays the current drawn from the battery by the inverter. Current should be in the green zone for continuous operation.
2.2 INPUT PANEL AND INSTRUCTION 2.2.1 FAN For cooling the inverter during operation 2.2.2 TERMINAL CONNECTOR Use red battery cable to connect (+) of the battery to the (+) terminal of the inverter. Then use the black battery cable to connect the (-) of the battery to the (-) terminal of the inverter. Tighten the screws of the DC input cables regularly. When connected to a battery, please make sure to turn on inverter first, before turning on the connected appliance(s).
2.2.3. CHASSIS GROUND LUG The inverter has a lug which is to connect the chassis of the inverter. The ground wire in the AC junction box on the output panel of the inverter is connected to the chassis . The chassis ground lug must be connected to a grounding point, which will very depending on where the inverter is installed. In a vehicle, connect the chassis ground lug to the chassis of the vehicle. In a boat, connect to the boat’s grounding system.
6. Low battery alarm on all the time and VOLTS indicator below 10.5V ( 21V for 2500W/24V inverter ) a. poor DC wiring Use proper cable and make solid connections b.Poor battery condition Change battery or use new battery Allow inverter cool down and reduce load if continuous operation required 7. No voltage output , OVER Thermal shutdown TEMP indicator light and load in excess of 2500W/250 amperes current input ( or 125A for 2500W / 24V inverter) 8.
DECLARATION OF CONFIRMITY We, Nedis B.V.
www.hqproducts.