3.2.1 CHARGING PROCESS
Via an inializaon roune, the voltage, temperature, short circuits and reverse polarity of
the inserted baery are checked.
Prior to starng the charging process, the temperature contacts (NTC contact, etc.) are
checked. If the temperature contacts are OK, the baery will be charged.
If the baery is too hot, it can stay in the charging staon, and when it has cooled down,
it will automacally charge.
If the red LED lights up, the charging process will start using the special HST frequency
modulaon impulse process
®
and charge the baery based on how depleted the baery is.
During the charging process, the voltage and temperature of the cells and the remaining
charging me are connuously monitored.
Taking all of the parameters into account, the charging current and remaining charging
me varies on a case-by-case basis. The installed fans switch on automacally, as needed
during each charging process.
Every charging process is recorded on a memory chip for subsequent evaluation.