4.3.4. Continuity test and Diode test
CAUTION
Before taking any in circuit resistance measurement, remove power from
the circuit to be tested and discharge all the capacitors.
Fig. 6: Taking Continuity test and Diode test
1. Rotate the switch on
CAP position
2. Pushing MODE key and select continuity test. The symbol is shown at display
3. Insert the red test lead plug into V CAPHz%Temp jack and the black test lead
plug into COM jack and perform continuity test on the object under test (see Fig. 6 –
left side). Buzzer emits sound if the measured resistance value is less about 60
4. Pushing MODE key and select diode test. The “ symbol is shown at display
5. Connect the red test leads to the anode of diode on test and the black test lead on the
cathode ones (see Fig. 6 – right side). Reverse position of test leads to reading reverse
polarization voltage
6. Displayed values within 0.4V and 0.7V (direct junction) and “OL” (reverse junction) are
correspondent to a correct result. A “0mV” value means a shorted device while a “OL
indication in both side means a broken device. Bargraph is disabled in diode test