3. Electrical parameters
3.1 Absolute Maximum Ratings
Table 2 Voltage Absolute Maximum Ratings
symbol
illustrate
minimum
Typical value
unit
VDD
Module power input voltage
–0.3
3.6 _
V
Tstg
storage temperature
-40
125
°C
Note: The use environment exceeding the rated value will damage the IC .
3.2 Recommended working conditions
Table 3 Input Voltage Range
symbol
illustrate
condition
detailed
minimum
Typical value
maximum value
unit
V CC
voltage
1.7
3.3
3.6
V
Top r
Working
temperature
- 40
8 5
°C
3.3 Power consumption parameters
Table 4 Power consumption
model
current
Remark
A VG
R MS
broadcast
0.35 mA _
1.94mA _
Broadcast interval period 200m s
connect
0.84mA _
2.16mA _
Mobile phone APP and blue night connection
Sleep D S3
3.526uA _ _
5.082uA _
DS3 mode supports GPIO, RTC Timer, LPUART and BLE Timer
wakeup. This mode can maintain one BLE connection.
Table 5 Electrostatic discharge parameters
symbol
name
standard
grade
maximum
value
unit
VESD (
HBM
)
Electrostatic discharge
voltage
(manikin)
TA= +25 °C Comply with JESD22-A114
2
2000
V
VESD (
CDM
)
Electrostatic discharge
voltage
(discharge device
model)
TA = +25 °C Complies with
JESD22-C101
II
500