Instruction Manual

7.1. Manual control: Same function as the arrow button on the right side of the interface. Switch to
display manual control interface and file preview interface .
7.2. Device status diagnose: Check and your Carvera in detail and debug. No need to use it when
Carvera runs in good condition. We will add a tutorial in the formal version of the instruction manual.
7.3. WiFi configuration: Refer to the previous WiFi setting instruction in chapter 4.
7.4. Wireless Probe Pairing: See the next chapter for detailed information.
7.5. Software Upgrade:
7.5.1. Controller: Controll software upgrade
7.5.2. Firmware: Firmware upgrade
7.5.3. Download: Link to the download page
7.5.4. UpgradeFor control software, just install the new version and you are ready to use. For
firmware, you need to upload it to the machine using the control software
7.5.5. Check at StartupCheck software updates and notice at the startup
Note: You need to click the Apply button to save all parameters after changing them
and rebooting the machine to apply changes. Parameter introduction and recommend-
ed settings are provided in the parameter list. We will add more detailed parameter
introductions and setting suggestions in the online instruction manual.
8.1. Parameters settings:
8.1.1. Basic parameters: Adjust functional parameters by requirements.
8.1.2. Advanced parameters: System-level of the machine. All set in the factory generally does
not need to be changed. Do not change it unless it has to.
8.1.3. Restore setting: Restore factory setting, or save current setting as factory setting.
Note: Carvera has already set the coordinate offset of the laser before delivery, only reset it when the
coordinates deviate. We will add relevant tutorials in the online instructions.
6Laser status and control
7Other functions
6.1. Symbol: Laser icon
6.2. Main data: Current laser rate
6.3. Sub-data: Laser power scale
6.4. Drop-down list:
6.4.1. Laser Status: Laser power scale
6.4.2. Enable Laser: Switch to laser mode. The working coordinates will be automatically updated
according to the preset offset. If there is a tool on the current spindle, Carvera will drop it first and
calibrate again to check the laser head’s height.
6.4.3. Laser Test: Performing a laser test after turn on the laser mode will trigger a low-power
laser beam for focus calibration.
6.4.4. Power Scaling: Set the laser power range by percentage. For safety reasons, the adjustment
amount range is limited from 50% to 200%.
28