Table 2-1 Requirements of installation scenarios
Installation
Scenario
Requirements
One AAU is installed
on a pole.
l The part of a pole for installing an AAU should have a diameter
of 60 mm to 300 mm (2.36 in. to 11.81 in.) and the recommended
wall thickness of a pole is greater than or equal to 4 mm (0.16 in.).
l If the part of a pole for installing an AAU has a diameter greater
than 300 mm (11.81 in.), an auxiliary pole is required for installing
the AAU.
Two AAUs are
installed on a pole.
l Two AAUs are installed back to back in most cases.
l The recommended wall thickness of a pole is greater than or equal
to 4 mm (0.16 in.).
l When AAUs are installed on the same level, the part of a pole for
installing the AAUs should have a diameter of 80 mm to 230 mm
(3.15 in. to 9.06 in.). When AAUs are installed on different levels,
the parts of a pole for installing the AAUs should have a diameter
of 60 mm to 230 mm (2.36 in. to 9.06 in.).
l If the part of a pole for installing AAUs has a diameter greater than
230 mm (9.06 in.), an auxiliary pole is required for installing the
AAUs.
Three AAUs are
installed on a pole.
l The recommended wall thickness of a pole is greater than or equal
to 4 mm (0.16 in.).
l When AAUs are installed on the same level, the part of a pole for
installing the AAUs should have a diameter of 80 mm to 230 mm
(3.15 in. to 9.06 in.). When AAUs are installed on different levels,
the parts of a pole for installing the AAUs should have a diameter
of 60 mm to 230 mm (2.36 in. to 9.06 in.).
l If the part of a pole for installing AAUs has a diameter greater than
230 mm (9.06 in.), an auxiliary pole is required for installing the
AAUs.
AAUs are installed
on a wall.
A wall should have a load-bearing capacity of 80 kg (176.37 lb).
An AAU is installed
on the top of a pole.
l The recommended wall thickness of a pole is greater than or equal
to 4 mm (0.16 in.).
l A flange plate must be installed on the top of a pole for attaching
an AAU to the pole.
l The recommended thickness of a flange plate is greater than or
equal to 6 mm (0.24 in.).
l To achieve neat installation, it is recommended that the diameter
of a pole be the same as that of a flange plate.
AAU3940
Installation Guide
2 Overview
Issue 01 (2015-01-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8