Table 10-1 Specifications of an AAU PGND cable
Cable End Connecting to
the AAU
End Connecting to
the Ground Bar
Color
AAU PGND cable OT terminal (M6, 16
mm
2
or 0.025 in.
2
)
OT terminal (M8, 16
mm
2
or 0.025 in.
2
)
Green and yellow
Procedure
Step 1 Prepare a PGND cable.
1. Cut the cables to the length suitable for the actual cable route.
2. Add OT terminals to both ends of the cables according to the instructions in Assembling
the OT Terminal and the Power Cable.
Step 2 Install the PGND cable.
1. Connect one end of the PGND cable with an M6 OT terminal to the ground bar of the
mounting kits for the AAU (shown by
), and use a torque wrench to tighten the ground
bolt to 4.8 N·m (42.48 lbf·in.).
Figure 10-9, Figure 10-10, and Figure 10-11 show the methods of installing PGND cables
when an AAU is installed on a pole, when an AAU is installed on a wall, and when an AAU
is installed on the top of a pole, respectively.