AP4130DN Quick Start Guide FCC ID: QISAP4030DN Issue 01 Date 2015-02-06 HUAWEI TECHNOLOGY CO.
AP4130DN Quick Start Guide About This Document Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.
AP4130DN Quick Start Guide About This Document About This Document Intended Audience This document describes hardware features of the AP4130DN and provides basic installation methods. This document is intended for:: Network planning engineers Hardware installation engineers Commissioning engineers Onsite maintenance engineers System maintenance engineers Symbol Conventions The symbols that may be found in this document are defined as follows.
AP4130DN Quick Start Guide About This Document Symbol Description NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration. Change History Changes between document issues are cumulative. The latest document issue contains all changes made in previous issues.
AP4130DN Quick Start Guide Contents Contents About This Document ................................................................................................................... iii 1 Indoor AP Overview..................................................................................................................... 6 1.1 Device Structure ........................................................................................................................................................... 6 1.
AP4130DN Quick Start Guide Contents 1 Indoor AP Overview About This Chapter The AP4130DN is deployed indoors and feature high reliability, high security, simple network deployment, automatic AC discovery and configuration, and real-time management and maintenance. Huawei indoor APs are especially applicable to places with simple building structure, small size, dense users, and high capacity demands, such as small-size conference rooms, bars, and leisure centers.
AP4130DN Quick Start Guide Contents Table in Table 1-1 shows the interface of AP4130DN. Table 1-1 Interfaces on AP4130DN No. Name Description 1 2.4G/5G/Dual-band antenna Connects a 2.4G/5G/Dual-band GHz antenna to the AP to transmit and receive service signals. 2 GE/PoE 10/100/1000M bit/s interface: connects to the wired Ethernet. The interface can connect to a PoE power supply to provide power for the AP. 3 DC power adapter The AP supports the PoE power supply and DC power supply.
AP4130DN Quick Start Guide Contents The AP4130DN has indicators located inside the panel. The indicators turn on after the AP is powered on. Figure 1-2 Indicator on the AP4130DN Table 1-2 Description of the indicator on the AP4130DN Type Color Status Description Default Green Steady on The AP is just powered on and the software is not started yet. Green Steady on After the system is reset and starts uploading the software, the indicator blinks green once.
AP4130DN Quick Start Guide Type Contents Color Status Description Hz) successfully on the AC (before the CAPWAP link is established). Fault Red Steady on The AP fails to go online on the AC (the CAPWAP link disconnects). A fault that affects services has occurred, such as a DRAM detection failure or system software loading failure. The fault cannot be automatically rectified and must be rectified manually. 1.3 Basic Specifications Table in Table 1-3 shows the specifications of AP4130DN.
AP4130DN Quick Start Guide Contents European Union RoHS: 2002/95/EC 2011/65/EU EN50581:2012 REACH: 1907/2006 WEEE: 2002/96/EC 2012/19/EU China RoHs: SJ/T 11363-2006 本信息适用于华为在中华人民共和国销售的电子信息产品 This information applies only to Huawei Electronic Information Products sold in the People’s Republic of China.
AP4130DN Quick Start Guide Contents 2 AP Installation About This Chapter 2.1 Preparing for Installation 2.2 Unpacking the Equipment 2.3 Determining the Installation Position 2.4 Installing the AP 2.1 Preparing for Installation This section describes safety precautions and tool preparations for AP installation. Safety Precautions Take proper measures to prevent injuries and device damage. Place the device in a dry and flat position away from any liquid and prevent the device from slipping.
AP4130DN Quick Start Guide Contents Table 2-1 Tools Phillips screwdriver Torque screwdriver Marker (M4) 3mm/5mm (M3-M6) ESD gloves Utility knife Cable cutter Diagonal pliers RJ45 crimping tool Wire stripper Network cable tester Multimeter Level 2.2 Unpacking the Equipment Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the equipment is rusted or soggy. Then, investigate causes and contact the supplier.
AP4130DN Quick Start Guide Contents 2.3 Determining the Installation Position When determining the AP installation position, comply with the following rules: Try to reduce the number of obstacles, such as walls, between the AP and user terminals. Install the AP away from electronic devices that can cause radio interference, such as the microwave oven. Install the AP in a hidden position that does not affect daily lives and work of residents.
AP4130DN Quick Start Guide Contents Figure 2-2 Mounting an AP(Unit: mm) 2.4 Installing the AP 2.4.1 Wall Mounting 1. Fix the mounting bracket to the wall, adjust the installation position, and use the marker to mark the drilling positions where expansion screws are installed. 2. Use a 6 mm drill bit to drill 25 mm to 30 mm deep holes in the drilling positions. Hammer the expansion tubes into the holes until the expansion tubes are completely embedded into the wall.
AP4130DN Quick Start Guide Contents Fix the mounting bracket to the wall and use the Phillips screwdriver to fasten three expansion screws into the expansion. 3. Align the mounting screws at the rear of the AP with the mounting holes on the mounting bracket and hang the AP on the bracket. Press the AP downwards to secure the AP on the wall. 2.4.
AP4130DN Quick Start Guide Contents 1. Remove a ceiling tile, determine locations of mounting holes based on the distance between two installation holes on the mounting bracket, use a hammer drill to drill hole on the ceiling tile, and fix the mounting bracket to the ceiling tile. 2. Hang the AP on the mounting holes by aligning the mounting screws at the rear of the AP with the mounting screws on the bracket and push the AP horizontally to secure the AP.
AP4130DN Quick Start Guide Contents bracket, hook the adjustable buckle to the T-rail, and secure the screw on the adjustable buckle to fasten the mounting bracket and T-rail. 2. Hang the AP on the mounting holes by aligning the mounting screws at the rear of the AP with the mounting screws on the bracket and push the AP horizontally to secure the AP. 1. Before fixing the adjustable buckle with a screw, you need to adjust the buckle to a proper position based on the T-rail width. 2.
AP4130DN Quick Start Guide Contents You need to purchase the security lock separately. 2.6 Connecting Cables Figure 2-3 and Table 2-2 shows interface and cable connection of AP4130DN。 Figure 2-3 Interfaces of the AP4130DN Table 2-2 Cable Connection No. 1 2 Issue 01 (2015-02-06) Cable Description Ethernet cable The network cables used are category-5 enhanced or higher twisted pairs. Ensure that the AP is connected to the Ethernet using the Ethernet cable that works properly.
AP4130DN Quick Start Guide Contents adapter delivered with the AP; otherwise, the AP maybe damaged. Pay attention to the following points when installing network cables Before connecting an Ethernet cable to the AP, use the cable test tool to check whether the cable is qualified. If the cable is unqualified, replace it. Do not connect the service network cable to the console port. Otherwise, the AP may be damaged when the PoE power supply is used.
AP4130DN Quick Start Guide 3 Logging In to the AP 3 Logging In to the AP About This Chapter 3.1 Logging In to the AP Through the Console Port 3.2 Logging In to the AP Using STelnet 3.3 Logging In to the AP Using a Web Client 3.1 Logging In to the AP Through the Console Port This section describes how to log in to the AP through the console port. After logging in to the AP, you can configure the AP using commands. Step 1 Connect a PC to the AP using a console cable.
AP4130DN Quick Start Guide 3 Logging In to the AP You can run commands to configure the AP. Enter a question mark (?) whenever you need help. 3.2 Logging In to the AP Using STelnet This section describes how to log in to the AP using STelnet. After logging in to the AP, you can configure the AP using commands. Before logging in to the device through STelnet, complete the following tasks: Starting the device properly Preparing network cables used to connect device interfaces.
AP4130DN Quick Start Guide 3 Logging In to the AP Figure 3-1 PuTTY Configuration page Step 3 Click Open. Enter the user name and password at the prompt, and press Enter. You have logged in to the device. (The following information is only for reference.) login as: admin Sent username "admin" admin@169.254.1.1's password: It is recommended that you change the initial user name and password after login.
AP4130DN Quick Start Guide 3 Logging In to the AP 3.3 Logging In to the AP Using a Web Client Pre-configuration Tasks Before configuring users to log in to the AP using HTTP, complete the following task: Configure reachable routes between the terminal and the AP. The web management system is enabled on the AP before delivery. The default IP address of the web management system is 169.254.1.1 and the mask is 255.255.0.0.
AP4130DN Quick Start Guide 4 Caution 4 Caution 4.