Table 2-2 General anti-interference requirements
Scenario Deployment Distance Requirement
Indoor
installation
l There should be at least a 7 m distance between antennas.
l The antennas should be placed at least 2 m from the 4G antennas of
the carrier.
l The antennas should be placed far away from electronic devices that
may produce interference, such as microwave ovens.
NOTE
If antennas are embedded into APs, the deployment distance requirements on the antennas are those on APs.
2.5 Installing the AP
NOTE
l Remove the protective film on the surface before installation to prevent electrostatic discharge.
l The installation of the AP6150DN is used as an example.
2.5.1 Installing the Device on a Wall
Mounting APs on a wall requires sheet metal mounting brackets and expansion screws. The
procedures are as follows:
1. Fix the mounting bracket to the wall, adjust the installation position, and use the marker
to mark the drilling positions where expansion screws are installed.
2. Use a 6 mm drill bit to drill 25 mm to 30 mm deep holes in the drilling positions.
Hammer the expansion tubes into the holes until the expansion tubes are completely
embedded into the wall.
AP6050DN & AP6150DN