Pay attention to the following points when bundling the cables:
l Different types of cables must be separately routed with the minimum spacing of 30 mm
and cannot be entangled or crossed. Cables should be parallel or separated using
dedicated separators.
l Bundled cables are closely arranged, straight, tidy, and undamaged.
l Cable ties are bound neatly facing the same direction, and those at the same horizontal
line must be in a straight line. Cable tie tails should be cut smoothly and evenly.
l Labels or nameplates must be attached to the cables after they are installed.
Connecting Antennas
Connect the antennas delivered in the installation accessory package of the AP to the RF ports
on the AP, tighten the nuts (with a torque of 0.8 N•m), and adjust antenna angles as required.
Connecting the Ground Cable
Use ground screws and ground cables to ground the AP. The ground cables need to be
prepared on site. The M4 OT terminal is used to connect to the AP and M6 OT terminals to
the ground bar. The type of OT terminals can also be determined according to site surveys.
Cut the cable into the required length according to site conditions.
Tighten the OT terminal for the AP with a torque of 3 N•m. The tightening torque for the
ground bar varies according to the OT terminals used.
l M4: 1.4 N•m
l M6: 4.8 N•m
l M8: 12 N•m
Ground cable deployment requirements are as follows:
l The ground cables must be connected to a group of ground bars.
l The bend radius of the ground cables must be larger than or equal to five times the cable
diameter.
l The ground cables must be buried underground or routed indoors and cannot be led into
the equipment room aerially.
l Both ends of the external conductor of the coaxial cable and those of the shield layer of
the shielded cable should have good electric contact with the metal shell of the
equipment they connect to.