No. Check Item
3 The power cables and PGND cables are intact and not spliced.
4 Terminals of the power cables and PGND cables are welded or cramped
firmly.
5 All power cables or PGND cables are not short-circuited or reversely
connected and must be intact with no damage.
6 The power cables and ground cables are separated from other cables and
bundled separately.
7 The working ground, protection ground, and surge protection ground
share the same group of ground bars.
8 Connectors of signal cables are complete, intact, and tightly connected.
The signal cables are not damaged or broken.
9 Labels on cables, feeders, or jumpers are clear and correct.
2.9 Powering on the AP
After the AP is powered on, observe indicator on the AP to determine the system running
status. For details, see 1.2 Indicator Description.
NOTE
Do not frequently power on and off the device.