RRU3203 V100R001C01 Installation Guide Issue: 01 Date: 2010-04-13 HUAWEI TECHNOLOGIES CO., LTD.
Contents Installation Tools …………………………………… 2 Space Requirements ………………………………… 3 Installation Modes …………………………………… 4 Installation Procedure ……………………………… 6 Components Delivered with the RRU …………… 6 Installing the RRU on a Metal Pole ………………..
Installation Tools Hammer drill (with bit 14) Heat gun ESD gloves Vacuum cleaner Phillips screwdriver Flat-head screwdriver (M3~M6) (M3~M6) Knife Claw hammer Torque socket Wire stripper Adjustable wrench Power cable crimping pliers Wire cutter (with the diameter of at least 32 mm [1.3 in.]) Torque wrench Combination wrench Level Torque screwdriver (21mm~21mm) for pole installation (17mm~17mm) for wall installation Marking pen Multimeter (with the diameter of no more than 10 mm [0.4 in.
Installation Options On a metal pole On a U-steel On an angle steel On a wall Metal pole m 0 8 ~ m 3 6 50 mm [2 in.] to 100 mm [3.9 in.] 63 mm [2.5 in.] to 75 mm [3 in.] Angle steel 30 mm [1.2 in.] to 50 mm [2.0 in.] 60 mm [2.4 in.] to 114 mm [4.5 in.] 63 mm [2.5 in.] to 75 mm [3 in.] The following figure describes the specifications for the metal pole, angle steel, and U-steel where the RRU is installed.
Dimensions and Installation Clearance a Dimensions of the RRU 381 mm [15.0 in.] 170 mm [6.7 in.] 485 mm [19.1 in.] b c Recommended Clearance for a Single RRU Minimum Clearance for a Single RRU 200 mm [7.9 in.] ≥300 mm [11.8 in.] ≥ 30 0m m m 00 8 ≥ 10 0m [11 .8 in. ] m .] 5 in . 1 [3 ≥6 00 mm [23 .6 m m 600 [3. 9 .] 6 in 23. [ m in. ] ≥500 mm [19.7 in.] d e m [15 .7 i n.] Minimum Clearance for Multiple Centralized RRUs 200 mm [7.9 in.] ≥300 mm [11.8 in.
Dimensions and Installation Clearance f ≥300 mm [11.8 in.] h g Recommended Horizontal Spacing for Two RRUs Installed in Parallel ≥600 mm [23.6 in.] Minimum Horizontal Spacing for Two RRUs Installed in Parallel ≥600 mm 100 mm [23.6 in.] [3.9 in.] i Recommended Vertical Spacing for Two RRUs Installed in Parallel 400 mm [15.7 in.] Minimum Vertical Spacing for Two RRUs Installed in Parallel ≥300 mm [11.8 in.] 200 mm [7.9 in.] ≥500 mm [19.7 in.] 300 mm [11.8 in.] ≥500 mm [19.7 in.] 300 mm [11.
Installation Procedure Start Prepare the installation Install the RRU on a metal pole Install the RRU on a U-steel Install the RRU on an angle steel Install the RRU on a wall Install the RRU cables Checking the RRU Hardware Installation Power on the RRU End Preparing the Installation Cover plate Attachment plate Auxiliary bracket Dual-nut bolt Main bracket Front Main and auxiliary brackets for the RRU 6 Back
Installing the RRU on a Metal Pole a Installing a Single RRU on a Metal Pole 1. Install the main bracket. When installing the main bracket, ensure that the contact piece on the bracket is fixed. 1200 mm [47.2 in.]~ 1600 mm [63 in.] You may fit one end of the auxiliary bracket on one dual-nut bolt assembly and then the other end on the other dual-nut bolt assembly during the installation. 2. Use an adjustable wrench to tighten the nut until the fastening torque is 40 N·m [354 lbf•in.].
Installing the RRU on a Metal Pole b Installing Two RRUs Back-To-Back on a Metal Pole 1. Install an RRU. For details, see page 7 Installing a Single RRU on a Metal Pole. 2. Install the main fixture for another RRU. 3. Reinstall the attachment plate and cover plate on the second RRU by interchanging their positions. M6X16 4.8 N•m [42.5 lbf•in.] 4. Install the second RRU on the main bracket.
Installing the RRU on a Metal Pole c Installing Multiple RRUs in Centralized Mode 1. Install the main fixture and the auxiliary fixture. For details, see page 7 Installing a Single RRU in Ordinary Mode. 2. Relocate the attachment plate. M6X16 4.8 N•m [42.5 lbf•in.] 3. Fit the tabs on the attachment plate of the RRU into the anchor slots on the main fixture. 4. Install the second main fixture. 5. Fit the tabs on the attachment plate of the second RRU into the anchor slots on the second main fixture. 6.
Installing the RRU on a Metal Pole c Installing Multiple RRUs in Centralized Mode 7. Install the fourth main fixture. 8. Fit the tabs on the attachment plate of the fourth RRU into the anchor slots on the fourth main fixture. 9. Four RRUs installed in centralized mode. 10 10. Six RRUs installed in centralized mode.
Installing the RRU on a U-Steel Plan view U-steel z The procedure for installing the RRU on a U-steel is the same as that for installing the RRU on a metal pole. z It is recommended that only one RRU be installed on a U-steel. Installing the RRU on an Angle Steel Plan view Angle steel z The procedure for installing the RRU on an angle steel is the same as that for installing the RRU on a metal pole. z It is recommended that only one RRU be installed on an angle steel.
Installing the RRU on a Wall 1. Place the auxiliary bracket at the installation position. Use a level to check that the auxiliary bracket is placed horizontally. Then, mark the anchor points by using a marking pen. ≥650 mm [25.6 in.] ≥650 mm [25.6 in.] 128 mm [5 in.] Level 126.5 mm [5 in.] 126.5 mm [5 in.] 1200 mm [47.2 in.] to 1600 mm [63.0 in.] RRU z It is recommended that the auxiliary bracket be 1,200 mm [47.2 in.] to 1,600 mm [63.0 in.] above the ground.
Installing the RRU on a Wall 3. Fit the auxiliary bracket on the expansion bolts downward, and then tighten the bolts by using a combination wrench 17 mm [0.7 in.]. M10 30 N•m [265.5 lbf•in.] Arrows are upwards 5. Install the RRU. 13 4. Install the main bracket.
Installing the RRU on a Wall 6. Install multiple RRUs. Recommended Clearance : ≥855 mm [33.7 in.] ≥855 mm [33.7 in.] ≥70 mm ≥70 mm [2.8 in.] [2.8 in.] Minimum Clearance: ≥655 mm [25.8 in.] ≥655 mm [25.8 in.
Installing the RRU Cables a RRU Cable Connections Single RRU Start Install PGND cable Antenna z When the length of the AISG multi-wire cable between the RRU and the RCU is not enough, you can choose the optional AISG extended cable between the RRU and the RCU. z If the coaxial cable is used for the RET antenna when the STMA or Smart Bias-Tee (SBT) is used, the OOK signals are required. Therefore, the port for the RET antenna needs to use the ANT_TX/RXA port.
Installing the RRU Cables b c Opening the Cover Plate of the RRU Cabling Cavity Cabling Cavity of the RRU Cable troughs for power cables Cable troughs for optical cables Cable troughs for power cables M4 Cover plate of the cabling cavity Cabling cavity Label for preparing the power cable d cable clip Waterproofing filler Cable Connections on the RRU z Before connecting a power cable, ensure that other end of the power cable not connected to any power supply.
Installing the RRU Cables e Closing the Cover Plate of the RRU Cabling Cavity M4 z The screws on the cover plate should be tightened until the fastening torque is 1.4 N·m [12.4 lbf•in.]. z Tighten the screws on the cover plate of the cabling cavity in the sequence shown in the figure. 1.4 N•m [12.4 lbf•in.] f RRU+APM30H Grounding the shielding layer of the power cable: a DC RRU power cable b CPRI optical cable Metal Shielding layer (25 mm [1 in.
Installing the RRU Cables g RRU+BBU Installed Against the Wall DC RRU power cable CPRI optical cable BBU power cable PGND cable LOAD6 DCDU panel facing the side, and the BBU panel facing downward LOAD0 z The DC RRU power cable is connected to one group of the LOAD0 to LOAD5 terminals of the DCDU-03B. z When the BBU and RRU are installed indoors, the DC RRU power cables need not to be grounded.
Installing the RRU Cables i RRU+TMC/TMC11H Grounding the shielding layer of the power cable: a DC RRU power cable b CPRI optical cable Metal Shielding layer (25 mm [1 in.]) PGND cable LOAD0 DC RRU power cable z At the end of the DC RRU power cable connected to the DCDU-03B, you need to make the shielding layer of the power cable into an OT terminal, and then connect the OT terminal to the PGND terminal of the corresponding port on the DCDU-03B.
RRU Hardware Installation Checklist No. Items 1 All self-made PGND cables are copper-based with the proper wire diameters. No breaking device such as switch and fuse is allowed for the electric connection of the grounding system. No short circuit is allowed. Each terminal on the grounding bar can be connected with only one wiring terminal of the PGND cable. 2 The RRU and the installation parts are securely installed. 3 The cover plate is securely installed on the cabling cavity of the RRU.
Appendix a Binding the RRU and Installation Components 1. Bind the RRU by leading the lifting rope along the lower part of the adapting piece and through the handle, bind the main and auxiliary brackets with the lifting rope, and then bind the steering rope with the handle of the RRU, as shown in the following figures. Lifting rope Steering rope Lower part of the adapting piece z When lifting the RRU and installation components to the tower, prevent the RRU from colliding with the tower.
Appendix b Adding OT Terminals by Using a Wire Stripper (Recommended) Adding the OT terminals to the power cable involves adding OT terminals to the RRU power cable and adding OT terminals to the shielding layer of the RRU power cable. Label for preparing the power cable -48V DC power cable -48V DC power wire OT terminals Shielding layer GND wire Determine lengths of power cables for different operations according to the scales on the inner side of the cover plate of the cabling cavity.
Appendix c Adding OT Terminals to the Shielding Layer of the DC RRU Power Cable Lead the wires made of the shielding layers through heatshrinkable tubes. Wrap the PVC insulating tape at the joint where the three wires meet. WARNING Do not damage the shielding layer of the power cable when cutting around the jacket.
Appendix d Waterproofing Outdoor Cables z The waterproof tape should be wrapped for an extra length of 20 mm [0.8 in.] away from the connectors at both ends. z The tapes should be wrapped around the connector from the lower part to the upper part. When wrapped for another layer, the tapes may not be cut. z When wrapping the waterproof tape, apply even force to extend the tape until the width of the tape is 1/2 of the original width.
Appendix f Pin Assignment of the RRU AISG Extension cable Pin of the AISG male connector Pin of the AISG female connector Wire Color Wire Type Instruction X1.1 X2.1 White/blue Twisted pair +12V Twisted pair DC Return A Twisted pair RS485 B Blue X1.7 X2.7 White/orange Orange X1.3 X2.3 White/green X1.5 X2.5 Green X1.6 X2.