User's Manual
RRU3278
Installation Guide
3 Information About the Installation
Issue 05 (2017-03-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
17
Figure 3-13 Angle steel-mounted RRU
Installing an RRU on a Wall
The wall on which RRUs are installed must meet the following requirements:
When a single RRU is installed, the wall can bear at least four times the weight of the
RRU.
Expansion bolts must be tightened with a torque of 30 N·m (265.52 lbf·in.) to ensure the
bolts work properly and the wall remains intact without cracks in it.
Figure 3-14 shows a wall-mounted RRU.