6 WebUI Operations
Issue 04 (2020-03-11)
Copyright © Huawei Technologies Co., Ltd.
138
Parameter
Description
connection port
Set the parameter to the AI port for DRM signals.
Startup current range
If the current of the AI port is within the setting range,
inverters are turned on. Otherwise, inverters are turned off.
Power Control
Set DI parameters based on the DRM requirements.
----End
6.4.7 Setting Remote Shutdown
Context
The SmartLogger provides four DI ports. The OVGR can connect to any DI port. The
SmartLogger shuts down the solar inverter over OVGR signals.
Figure 6-50 Networking
When setting this function, ensure that the user-defined DI port is not occupied. Otherwise,
the setting will fail.
Procedure
Step 1 Set remote shutdown parameters.