User's Manual
Table Of Contents
- About This Document
- Contents
- 1 Safety Information
- 2 Product Overview
- 3 Device Installation
- 4 Cable Connections
- 4.1 Connecting Cables to the SmartLogger
- 4.1.1 Preparing Cables
- 4.1.2 Connecting a PE Cable
- 4.1.3 Connecting an RS485 Communications Cable
- 4.1.4 Connecting an MBUS Cable
- 4.1.5 Connecting a DI Signal Cable
- 4.1.6 Connecting the Output Power Cable
- 4.1.7 Connecting the AI Signal Cable
- 4.1.8 Connecting the DO Signal Cable
- 4.1.9 Connecting the Ethernet Cable
- 4.1.10 Connecting Fiber Jumpers
- 4.1.11 Installing a SIM Card and a 4G Antenna
- 4.1.12 Connecting the 24 V Input Power Cable
- 4.2 Connecting Cables to the SmartModule
- 4.2.1 Preparing Cables
- 4.2.2 Connecting the PE Cable
- 4.2.3 Connecting the Ethernet Cable
- 4.2.4 Connecting the 12 V Power Input Cable
- 4.2.5 Connecting the RS485 Communications Cable
- 4.2.6 Connecting the DI Signal Cable
- 4.2.7 Connecting the Output Power Cable
- 4.2.8 Connecting the AI Signal Cable
- 4.2.9 Connecting the PT Signal Cable
- 4.2.10 Connecting the 24 V Power Input Cable
- 4.1 Connecting Cables to the SmartLogger
- 5 System Operation
- 6 WebUI Operations
- 6.1 Introduction to WebUI
- 6.2 Device Commissioning
- 6.3 Parameter Settings
- 6.3.1 Setting User Parameters
- 6.3.2 Setting Parameters for Connecting to the Management System
- 6.3.3 Setting RS485 Communications Parameters
- 6.3.4 Setting Parameters for the Slave SmartLogger
- 6.3.5 Setting MBUS Parameters
- 6.3.6 Setting SUN2000 Parameters
- 6.3.7 Setting PID Module Parameters
- 6.3.8 Setting Power Meter Parameters
- 6.3.9 Setting EMI Parameters
- 6.3.10 Setting STS Parameters
- 6.3.11 Setting IEC103 Device Parameters
- 6.3.12 Setting Parameters for a Custom Device
- 6.3.13 Setting IEC104 Device Parameters
- 6.4 Power Grid Scheduling
- 7 Device Maintenance
- 8 FAQ
- 8.1 How Do I Connect the SmartLogger to the SUN2000 App or FusionSolar App?
- 8.2 How Do I Set FTP Parameters?
- 8.3 How Do I Set Email Parameters?
- 8.4 How Do I Change the SSID and Password of the Built-in WLAN?
- 8.5 How Do I Use DI Ports?
- 8.6 How Do I Use DO Ports?
- 8.7 How Do I Use the USB Port?
- 8.8 How Do I Change a Device Name?
- 8.9 How Do I Change the Communications Address?
- 8.10 How Do I Export Inverter Parameters?
- 8.11 How Do I Clear Alarms?
- 8.12 How Do I Enable the AI1 Port to Detect SPD Alarms?
- 8.13 Which Models of Power Meters and EMIs Are Supported by the SmartLogger?
- 8.14 How Do I Check the SIM Card Status?
- 9 Technical Specifications
- A Product User Lists
- B Domain Name List of Management Systems
- C Acronyms and Abbreviations
SmartLogger3000
User Manual
9 Technical Specifications
Issue 04 (2020-03-11)
Copyright © Huawei Technologies Co., Ltd.
176
Parameter
Specifications
The SmartLogger3000A01AU supports the
following frequency bands:
LTE FDD: B1, B2, B3, B4, B5, B7, B8, B28
LTE TDD: B40
WCDMA: B1, B2, B5, B8
GSM: 850MHz/900 MHz/1800
MHz/1900MHz
WLAN (local maintenance using app)
2.4G
RF Bands of the 4G Module (SmartLogger3000A01EU and
SmartLogger3000A03EU)
Frequency Band
Tx
Rx
WCDMA Band 1
1920–1980 MHz
2110–2170 MHz
WCDMA Band 5
824–849 MHz
869–894 MHz
WCDMA Band 8
880–915 MHz
925–960 MHz
GSM 900
880–915 MHz
925–960 MHz
GSM 1800
1710–1785 MHz
1805–1880 MHz
LTE Band 1
1920–1980 MHz
2110–2170 MHz
LTE Band 3
1710–1785 MHz
1805–1880 MHz
LTE Band 5
824–849 MHz
869–894 MHz
LTE Band 7
2500–2570 MHz
2620–2690 MHz
LTE Band 8
880–915 MHz
925–960 MHz
LTE Band 20
832–862 MHz
791–821 MHz
LTE Band 38
2570–2620 MHz
LTE Band 40
2300–2400 MHz
LTE Band 41
2555–2655 MHz
Output Power of the 4G Module (SmartLogger3000A01EU and
SmartLogger3000A03EU)
Frequency Band
Standard Value
(Unit: dBm)
Remarks (Unit:
dB)
GSM 900
GMSK (1Tx Slot)
33
±2