User's Manual

Table Of Contents
SmartLogger3000
User Manual
6 WebUI Operations
Issue 04 (2020-03-11)
Copyright © Huawei Technologies Co., Ltd.
70
Context
After installing or replacing a device or SmartLogger, you need to set device parameters and
add the device.
6.2.1 Preparations and WebUI Login
Prerequisites
The operating system of Windows 7 or later is supported.
Browser: Chrome 52, Firefox 58, or Internet Explorer 9, or a later version is
recommended.
Procedure
Step 1 Connect the network cable between the network port of the PC and the WAN or LAN port of
the SmartLogger.
Step 2 Set the IP address for the PC on the same network segment as the SmartLogger IP address.
Connected
Port
Item
SmartLogger
Default Value
Example PC Setting
LAN port
IP address
192.168.8.10
192.168.8.11
Subnet mask
255.255.255.0
255.255.255.0
Default gateway
192.168.8.1
192.168.8.1
WAN port
IP address
192.168.0.10
192.168.0.11
Subnet mask
255.255.255.0
255.255.255.0
Default gateway
192.168.0.1
192.168.0.1
If the IP address of the WAN port is on the 192.168.8.1–192.168.8.255 network segment, the IP
address of the LAN port is automatically switched to 192.168.3.10, and the default gateway is
192.168.3.1. If the connection port is a LAN port, the network configuration of the PC needs to be
adjusted accordingly.
It is recommended that the PC be connected to the LAN port of the SmartLogger or the GE port of
the SmartModule. When the PC is connected to the GE port of the SmartModule, adjust the network
configuration of the PC to the configuration mode when the PC is connected to the LAN port of the
SmartLogger.
Step 3 Set LAN parameters.