ManualsBrandsHubbell ManualsCommercial Dish Washing EquipmentBooster Heater Electric, 12.0 kW with 16-Gallon Storage Capacity, ASME Stamped Stainless Steel Tank with CFC/HCFC Free Closed Cell Foam insulation, Electronic Display Controller with Low Water Cut-Off and Leak Detection, Stainless Steel Exterior, Pressure
11
e. No valve of any type to be installed between the relief valve and tank or in the
drain line.
6. A shock absorber is recom
mended in the hot
water outlet line to soften the water
ham
mer caused by automa
tic dishwasher solenoid valves.
7. Install the in-line pressure and tem
perat
ure gauge, when supplied, in the entering
cold/warm water line. If supplied, install the optional second dial temperature and
pressure gauge in the outlet line. The tem
per
ature sensing element must be in the hot
water stream
and the gauge must be m
ounted upright.
FILLING THE HEATER
1. Open the valve to the cold/warm water inlet and allow the heater and piping system to
com
pletely fill, as indicated by a steady fl
ow of water through the dishwasher rinse
nozzles.
NOTE
: Flush the tank at full flow for 10 m
inutes prior to putting into service.
ELECTRICAL INSTALLATION
1. Enter the base through the factory cut KO’s with properly sized feeder leads, See
Wiring Chart. Single-phase installations require two (2) leads. All Hubbell 3-phase
heaters are intended for use with a 3-wire delta system plus ground. No neutral is
required. For a 4-wire plus ground system, install 3 legs of power plus the ground and
terminate the neutral leg.
2. Install these power leads into the box lugs on the power distribution block or magnetic
contactor, as required.
3. Connect incoming ground wire to ground lug supplied.
4. Check for proper grounding. Check for AC millivolts (mV) between the ground
connection at the booster and the inlet piping past the optional dielectric union (on the
building side, not the booster side). There should be zero potential/millivolts (mV). If
not zero, then the piping should be re-grounded.
5. All other electrical connections are made at the factory; therefore, no other electrical
connections are necessary.
6. Check all connections, including factory connections, for tightness.
OPTIONAL XB1 EXPANSION BOARD (used for temperature alarm / interlock)
1. If desired, the XB1 can be used as an alarm relay or a temperature interlock at a
setpoint other than the water tem
p
erature setpoint on the booster heater.
2. If the XB1 is not factory installed, m
ount th
e XB1 to the control panel and connect the
XB1 to the T1000 control board with the factory supplied cable between JX4 on the
XB1 and J1 and J4 on the T1000 and connect the ground between JX6 on the XB1
and J8 on the T1000.
3. Make connections as required to the relay term
inal block. When the temp
erature drops
below the XB1 setpoint the relay is open between N
ormally Open (NO) and Common