ii. Low water detection – sets the low water detection on or off.
1. LOn, for low water on. (Factory Default)
2. LOF, for low water off.
iii. Low water reset – sets the low water reset for either autom
atic or ma
nual
1. LAU
, for low water automa
tic reset. (Factory Default)
2. LAn
, for low water ma
nual reset.
iv. Tem
perature units – sets the temp
erature units to either degrees
Fahrenheit or Celsius.
1. DEF, for degrees Fahrenheit. (Factory Default)
2. DEC, for degrees Celsius.
v. Differential – sets the number of degrees below setpoint that the heater
will resum
e
heating after it has achieved setpoint.
1. d ##, where ## is the differential in degrees (1 to 20). (Factory set
at 02)
vi. Display – sets the display to either setpoint or actual tem
p
erature.
1. dSS
, for display setpoint temp
erature. (Factory Default)
2. dSt, for display actual temperature.
vii. Heater Interlock – sets the heater interlock m
ode to on or off. (Only
available with r23 or later software).
1. HoF, to disable the 24-volt interlock feature. (Factory Default)
2. Hon, to enable the 24-volt interlock feature.
viii. XB1 Tem
perature Setpoint – sets th
e setpoint for the operation of the
XB1 relay operation.
e. To leave the configuration menu, wait 5 seconds without pushing any buttons or
press the UP and DOWN buttons sim
u
ltaneously.
5. To reset any high-lim
it, no probe, or low water (when in manual reset m
ode) fault
condition, press the RESET button.
6. Display
a. By default the display will show the setpoint of the booster heater.
b. The decim
a
l points on the display, as shown below, indicate that the controller
is calling for a contactor to pull in. If three or more contactors are installed, the
third decim
al point is used for all rema
ining contactors.
ANNUAL INSPECTION
1. Monitor water temperature
a. Let water heater com
pletely heat to a designated temp
erature setting.
b. After controller satisfies (that is, when the m
a
gnetic contactor actually clicks
off), draw water from
as close as possible heater outlet and m
easure the
temperature.
c. Compare the water temperature of outlet water to the temperature setting of
the display when it satisfies. Norm
al variation between the
two points is
approxim
a
tely + 5°F.