1. To ensure the success of the fixture installation, the following instructions and
diagram(s) should be read and understood.
2. All electrical connections must be made in accordance with the National Electric
code and local codes and ordinances. If you are uncertain of the methods of installing
electrical wiring and lighting fixtures secure the services of a qualified licensed
electrician.
TOOLS NEEDED
Blade screwdriver, phillips screwdriver, slip joint pliers or small adjustable wrench,
wire cutter/stripper, electrical current tester, stepladder and electrical tape.
INSTALLATION PREPARATION
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE
LIGHTING FIXTURE IS TO BE ATTACHED. Turn circuit breaker to the “off”
position or completely remove the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to which of the wires in
the outlet box the fixture was attached. DO NOT SEPARATE MULTIPLE
TWISTED WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE
THE INSULATION OF OLDER WIRING. In regular circumstances the BLACK
wire will be the “Hot” lead and the WHITE wire will be the “Neutral” or “Common”
lead. A GREEN or BARE COPPER wire is the “Ground”. In older buildings it is always
good practice to reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on an octagon box. The box must be
securely mounted to the structure of the building.
FIXTURE INSTALLATION
1.Remove the fixture and parts bag(s) from the carton. Before discarding the carton,
double check packing to make certain that all parts are found.
2. Attach the crossbar to the outlet box. (The green screw should face the floor)
3. Fasten the bare ground wire to the green or bare copper wire in the outlet box or
the green screw on the crossbar.
NEVER FASTEN THE GROUND WIRE TO THE BLACK OR "HOT" WIRE
!FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN
SERIOUS INJURY OR DEATH !
4. Fasten the fixture lead with the ridge(s) to the white wire in the outlet box.
Fasten the wires together with an approved fastener (wire nut) Sterting about 1" below
the fastener, tightly wrap the connetion with electrical tape so that the tape seals the
end of the fastener.Make sure that there is no exposed wire or strands that
could cause a dangerous short circuit !
5. Connect the black fixture wires to the black wire in the outlet box. Fasten the
joined wires as in step 3.
6. Attach the ceiling pan to the outlet box and secure it by screws.
7. Attach the glass to the ceiling pan and screw the glass into the ceiling pan.
8. This fixture design for wet location, if you install this fixture to the wet
location area, after finish install the fixture to the ceiling, please use silicone
caulking compound seal all around the gap of the ring to provide a
watertight seal.
9. Restore power to circuit at breaker or fuse box.