Installation Sheet

2210, 2211, 2212
Thank you for purchasing our lighting fixture.
Please clean with a soft, dry cloth ONLY! Do not
use cleansers.
www.h
udsonvalleylighting.com
GENERAL
1. To ensure successful installation, the following instructions and diagram(s) should
be read and understood.
2. All electrical connections must be made in accordance with the National Electric
code and local codes and ordinances. If you are uncertain how to install electrical
wiring and lighting fixtures, secure the services of a qualified licensed electrician.
TOOLS NEEDED
Blade screwdriver, phillips screwdriver, slip joint pliers or small adjustable wrench,
wire cutter/stripper, electrical current tester, stepladder and electrical tape.
INSTALLATION PREPARATION
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING
FIXTURE IS TO BE ATTACHED. Move the appropriate circuit breaker to the “off
position or completely remove the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to which of the wires
i
n the outlet box the fixture was attached. DO NOT SEPARATE ANY OTHER
WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF
OLDER WIRING. In regular circumstances the BLACK wire will be the “Hot” lead
and the WHITE wire will be the “Neutral” or “Common” lead. A GREEN or BARE
COPPER wire is the “Ground”. In older buildings it is always good practice to
reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on a standard round or octagon box. The
b
ox must be securely mounted to the structure of the building.
FIXTURE INSTALLATION
1. Remove the fixture, metal shades, glass diffuser and parts bag(s) from the carton.
Before discarding the carton, double-
check packing to make certain that all parts are
2. This fixture is supplied with a 3-piece stem. There is one 6" section, one 12"
section and one 18" section. This feature allows the fixture to be mounted with a
stem up to 36" in length in 6" increments.
3. This fixture is supplied with a swivel. By rotating the canopy the fixture may be
mounted to an angled ceiling.
4. Determine the overall desired length of the fixture. For general convenience
the fixture is shipped with the leads threaded through the stems. If the stems are
rearranged or additional stems are added, tape the ends of the leads to a stiff
wire (coat hanger) to aid in pulling them through the stems.
5. (Starting at the back), thread the 2 longest screws into the crossbar. (The
green ground screw is the front ). Attach the mounting strap to the outlet box.
(The green screw should face out).
6. Thread the small hex nuts onto the screws. Adjust the screws so they extend
3/16" beyond the canopy of the fixture, Lock the hex nuts against the crossbar.
7. Fasten the green fixture wire to the green or bare copper wire in the box or
fasten it to the crossbar with green screw provided.
NEVER FASTEN THE GROUND WIRE TO THE BLACK OR “HOT” WIRE!
FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS
INJURY OR DEATH!
8. Fasten the white fixture wire to the white wire in the out
let box. Fasten the wires
together with an approved fastener (wire nut). Starting about 1” below the fastener,
tightly wrap connection with electrical tape so that the tape seals the end of the
fastener. Make sure that there is no exposed wire or strands that could
cause a dangerous short circuit !
9. Connect the black fixture wires to the black wire in the outlet box.
Fasten the joined wires as in step 8.
Continued next page.
lever
Retaining ring

Summary of content (4 pages)