1027144–0001 Revision D Maintenance 10–11RT installation
6. Place the CCM in its ESD protective packaging.
7. Remove all SSIs:
a. Using a piece of tape on the SSI front panel, mark the
slot number where each SSI was installed.
b. Loosen the thumbscrews at each end.
c. Using an ESD wrist strap connected to a chassis
ground terminal, slide the SSI out of its slot.
8. Place each SSI in ESD protective packaging.
9. If the IDU chassis is rack mounted, remove the four
mounting screws and remove the chassis from the rack.
10. Remove the rack mounting brackets from the chassis.
Installing the replacement IDU chassis
Refer to the instructions in chapter 3 to:
11. Install the replacement chassis in a rack, if the original
chassis was installed in a rack (section 3.2).
12. Re–connect power to the IDU chassis power supply
(section 3.3).
13. Conduct a power–on test (section 3.3).
14. Re–install the CCM (section 3.4).
15. Re–install the SSIs (section 3.5).
Install each SSI in the slot it was in before. Refer to the slot
numbers you marked on the tape on each SSI.
16. Re–connect the IFL cable and all other cables to the CCM
and SSIs.