User's Manual
Table Of Contents
- Title page
- Contents
- About this manual
- Safety information
- Ch 1 - Installation summary
- Ch 2 - Prerequisites
- Ch 3 - Indoor equipment
- Ch 4 - Installing IFL cables
- Ch. 5 - Installing mast mounts
- Ch 6 - Installing ODUs
- Ch 7 - Commissioning the RT
- Ch 8 - Final steps
- Ch 9 - Troubleshooting
- Ch 10 - Maintenance
- App A - Acronyms
- App B - Standards compliance
- App C - Terminating the IFL cable
- Index
1027144–0001 Revision D C–10 Terminating the IFL cable RT installation
7. While holding the connector assembly together snugly,
position the HCT–231 crimping tool, at setting 0.475, onto
the area shown in figure C-11 and securely crimp the crimp
ring into place.
CAUTION
To avoid damaging the connector body,
make sure the crimping tool does not
touch the connector jam nut.
Crimp
hb024
Maximum gap
(exposed braid):
0.03 inch (0.8 millimeter)
Best if no gap.
Figure C-11 Crimp location
Note: If the crimp ring slips and results in a gap greater
than 0.03 inch (0.8 millimeter) between the crimp ring and
the connector collar, reject the connection. Cut off the
connector and start over.