Installing indoor RT equipment 3–7
RT installation
2. Screw the two upper mounting screws into the rack (one on
each side), at the desired installation height. Refer to figure
3-5.
Do not tighten the screws all the way—this allows you to
hang the chassis by the top “teardrop” holes on the brackets
(in step 3).
(The four mounting screws that screw into the rack should
be provided with the rack.)
Figure 3-5 Installing the IDU chassis in a rack
hb033
Rack
Front
Leave part
of the upper
mounting
screws
exposed
so you can
hang the
brackets
on them.
3. Place the chassis into the rack, and slip the top hole of each
bracket over the heads of the upper mounting screws in the
rack.
4. Support the chassis with one hand while you install and
tighten the two lower screws.
5. Tighten the two upper screws.