Installing indoor RT equipment 3–25
RT installation
Test the CCM for proper operation, as follows:
1. Apply power to the IDU chassis.
2. Observe the LEDs on the CCM front panel:
OK
STATUS
ALARM
()Red
On: Hardware failure
()Green
On: Normal operation
or CCM startup
T0009052
3. Also observe the CCM startup diagnostics (SUDS) on the
CCM’s front panel LCD:
SUDS start on powerup. While they run, the CCM front
panel shows the following messages, in the sequence
shown.
Equipment function is normal when you see the
messages shown below and no failure messages.
Initial powerup
SUDS CPU Reg OK
SUDS DRAM OK
CPU registers and dynamic
RAM are tested.
Timer test
SUDS Timer Test
Timers are tested.
Watchdog timer test
SUDS WDT Test
The watch dog timer
is tested.
PCI test
SUDS PCI Test
The PCI controller is tested.
CCM power–on test
(SUDS)