1027144–0001 Revision D 3–26 Installing indoor RT equipment
RT installation
Static dual port RAM test
SUDS SDPRAM Test
Static dual port RAM is tested.
Serial port 1 test
SUDS Ser 1 Test
Serial port 1 is tested.
Serial port 2 test
SUDS Ser 2 Test
Serial port 2 is tested.
Successful test completion
This message indicates that startup diagnostics have
successfully completed:
SUDS Completed
Failure indication
If a failure occurs during any of the tests listed above,
the LCD message sequence stops. The LCD shows the test
that failed on the first line and FAILED (flashing) on the
second line, as in the example below.
SUDS Ser 2 Test
FAILED
This screen indicates that
serial port 2 failed diagnostics.
The LCD remains inactive unless you power the CCM off,
then on. This restarts SUDS.
If any CCM component fails, replace the CCM.
After SUDS are complete, the LCD displays the CCM boot
up sequence. At this point, you only need to verify that
SUDS have completed.
Leave power on while you install the SSIs (next).