User's Manual

Table Of Contents
1027144–0001 Revision D
Installing indoor RT equipment 3–37
RT installation
Figure 3-26 ESD wrist strap
rt063
Wrist
strap
Connect to IDU or
EIDU chassis
ground terminal.
2. Wrap the ESD strap snugly around your wrist and connect
the alligator clip to one of the ground terminals on the front
of the chassis power supply.
3. Remove the FEM from its ESD protective packaging.
Retain the packaging in case it is necessary to return the
FEM for repair.
4. Slide the FEM into the guides on each side of the chassis
slot and push it firmly into place until the front of the FEM
is flush with the front of the chassis.
T0009058
IDU
EIDU
EIDU FEM
IDU FEM
CCM slot
SSI
slots
5. Tighten the thumbscrews at each end of the FEM.
To tighten the thumbscrews, push them toward the IDU
chassis and turn them clockwise. To fully tighten the
thumbscrews, use a Phillips screwdriver.