User's Manual

Table Of Contents
1027144–0001 Revision D 4–12 Installing IFL cables
RT installation
Follow these steps to ground the lightning arrestor:
1. Connect one end of the ground cable (No. 6 AWG or
greater, green) to the lightning arrestor ground bar, as
shown in figure 4-10.
Figure 4-10 RT lightning arrestor grounding connections
rt051
To ground
point
Ground cable
No. 6 AWG or greater
Single-hole compression lug
Ground bar
2. Route the ground cable to the ground point.
When routing the ground cable, you must:
Secure the ground cable at 5–foot (1.5–meter)
intervals.
Keep the ground cable at least 3 feet (0.9 meters)
away from non–grounded metal objects.
Make sure all bends in the cable have a sweeping
radius of more than 8 inches (20.3 centimeters).
3. Connect the RT lightning arrestor to the same ground
(reference) point as the ODU ground. See section 6.10.
4. Apply anti–oxidant (HNS 9008224–0002) to each ground
lug.
5. Apply 1/2–inch (13–millimeter) heat shrink tubing (HNS
9007488–0005) to each ground lug after the connection is
complete.
Important: You must slip the heat shrink onto the cable
before you make the connections.
Grounding the RT
lightning arrestor