10271450001 Revision D Commissioning HTs 7–7Hub installation
Verify the status of the ODU as follows:
1. Press Enter on the CCM front panel. (The CCM must be in
operational mode, as indicated by HT Enabled on the
LCD.)
The LCD shows:
Main Menu
Status
2. Press Enter, to go to (select) the Status menu:
Status
CCM
3. Press the up arrow button twice to scroll to the ODU status
option:
Status
ODU
4. Press Enter to show the ODU status:
ODU
OK
The possible status conditions for CCMs, SSIs, and the
ODU are:
OK
Degraded
Failed
Unknown
(as explained on page 6–39)
To exit the Status menu, scroll to Exit, and then press Enter.
If a failure is indicated for any component, replace that
component. Run SUDS again, and check the status of the new
component.
At this point, HT commissioning is complete, except for the HT to
RT tests described in section 7.3. You may or may not be able to
complete these tests, depending on whether or not other network
components are installed and operational. (See the test
requirements listed in section 7.3.)
Leave the HT powered on for testing and operation.
Verify ODU status