Installation Manual

1027144–0001 Draft – Revision D.01
Commissioning the RT 7–9
RT installation
5. Scroll to the correct ODU frequency. Scroll up (up arrow)
for a higher frequency; scroll down (down arrow) for a
lower frequency.
Important: If you do not see the correct frequency on the
LCD, you may have installed the wrong ODU for the site
(high band instead of low band, or vice versa). In this case,
the LCD will not display the correct frequency as one of the
available choices. If the wrong ODU is installed, you will
not be able to proceed until the correct ODU is installed.
6. Press Enter when the LCD shows the correct frequency, for
example:
Freq Set
8B4
The LCD shows Freq Acq in Prog (frequency acquisition
in progress) and then Acq Ack: HT 2 (acquisition
acknowledged—in this example, frequency acquired from
HT 2).
Note: The LCD will display Acq Denied (acquisition
denied) if:
The RT’s ESN has not been entered in the EMS
database, or
The RT is pointed toward the wrong HT.
Go to the roof and proceed with steps 7 through 13.