Installation Manual

1027144–0001 Draft – Revision D.01 7–24 Commissioning the RT
RT installation
RT to HT fractional DS3 test results
RT location: ____________________________________________
Number of DS1s tested ______
Test successful? ___ Yes ___ No RSSI __________
If not successful, complete:
Bit error rate _______________ Frame slips _______________
Frame errors _______________ Clock slips ________________
Trouble report generated? ___ Yes ___ No
If yes, report number: ____________________
If applicable: Faulty module part number ______________________
Serial number _____________________
If applicable: Replacement board part number __________________
Serial number______________________
BER test printout attached? ___ Yes ___ No
Comments:
_________________________________________________________________________________
_________________________________________________________________________________
Tested by (print name and sign): _______________________________________________________
Customer (print name and sign): ________________________________________________________
Date __________________________