Installation Manual

1027144–0001 Draft – Revision D.01
Installing indoor RT equipment 3–5
RT installation
The IDU can be used on a tabletop or installed in a 19–inch
(48.3–centimeter) rack. With optional adapter brackets, the IDU
can also be installed in a 23–inch (58.4–centimeter) rack.
Safety guidelines
Observe these guidelines from Underwriters Laboratories Inc.
(UL) when you install IDU chassis in a rack (any rack):
Make sure the power requirements of the IDU chassis plus
the cumulative power draw of other equipment in the rack
do not overload the supply circuit and/or wiring of the rack.
The IDU weighs about 20 pounds (about 9 kilograms).
Have someone help you when you lift the IDU chassis to
install it in the rack.
Always load the rack from bottom to top to ensure a stable
and safe rack.
Installation of the IDU chassis within the rack system
should not reduce air–flow within the rack.
The maximum recommended ambient temperature for the
IDU chassis is 50 °C (122°F).
While installing the IDU chassis into the rack, make sure
you maintain a proper earth grounding for the equipment.
Mounting options
Rack mounting