Operating Instructions EMAX designs and manufactures products for safe operation. However, operators and maintenance persons are responsible for maintaining safety. All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation. Keep these instructions for reference. Silent Air Portable Air Compressor Model # : HP15P005SS UPC: 815002013978 EMAX Compressor 1000 Cass Dr., Clayton, OH 45315 USA 866.294.
HULK Power Air Compressors Contents Model Specifications…………………………… 2 Installing the air filter …………………… 8 Description………………………………………… 3 Operation …………………………………………… 8 Get to know your compressor…………… 3 Before operating your new air compressor: …………………………………… 8 Safety Information……………………………… 4 General Overview………………………………… 8 Basic Guidelines………………………………… 4 Installation and Location………………… 8 Breathable Air………………………………… 4 Connecting to Power Source…………… 8 Pressurized Components………………… 4 Extension
Silent Air Series Description 10 8 9 11 5 fig 1 3 1 3 2 3 Get to know your compressor Please refer to fig 1. 1.TANK DRAIN VALVE (located on bottom of tank) - The tank drain valve can be opened to allow moisture and compressed air to be released from the air tank. valve end to check that it is working properly. 5.RESERVOIR AIR PRESSURE GAUGE Indicates pressure of compressed air built up in the tank. 6.
HULK Power Air Compressors Always make sure that the compressor power switch is in the OFF position before performing any maintenance or plugging the compressor into a power supply. 7. AIR FILTER Ensures the air being pressurized is free of the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. Basic Guidelines 1. Allow only trained, authorized persons who have read and understood these operating instructions to use this compressor.
Silent Air Series welding, drilling or other modifications. Such modifications may weaken the air tank and cause a hazardous condition. 2. Allow sufficient space around compressor for maintenance access and adequate airflow. Mount unit leaving a minimum of 15 inches (38 cm) of clearance. 5. If the air tank develops a leak, replace it immediately. Never repair, weld or make modifications to the air tank or its attachments. 6. Do not make adjustments to the factory-set pressures. 7.
HULK Power Air Compressors 9. If the tool is equipped with three-pin plug, it should be plugged into a three-pin electrical socket. Never remove the ground pin. as death or serious injury may result. 7. Make sure to provide adequate ventilation while operating the compressor. If combustible substances are spilled, clean up immediately. 10. Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There is an increased risk of electric shock if your body is grounded.
Silent Air Series strict adult supervision. 19. The air pressure switch is set at the factory for optimum performance of your equipment. Never attempt to bypass or remove this switch as serious damage to equipment or personal injury could result from excessive air pressure. 6. S tore idle tools out of the reach of children and untrained persons. Tools may be dangerous in the hands of untrained users. 20. Compressed air from the unit may contain carbon monoxide.
HULK Power Air Compressors used (C, fig 5) it must be attached to the metal screw of the receptacle. check that all pipes and hoses are firmly connected. ●● Do not use the air compressor if any damage is found. If damaged, have an authorized service center inspect and test the air compressor to ensure that is working properly. ●● Pull the ring on the safety valve before each use to make sure the valve is functional.
Silent Air Series cord is properly wired and in good electrical condition. ●● Maximum length of extension cord should be 50 feet (15 meters). Minimum wire size of extension cord should be 12 gauge. Pressure Switch 2. Check that the pressure switch is pointed up, in the OFF position (fig 9.0). Attaching an air hose Your air compressor is supplied with a 1/4" pushconnect air coupler (fig 7).
HULK Power Air Compressors Shutting off your compressor 1. Move the pressure switch clockwise to the OFF position (fig 9.0). 2. Unplug the compressor from the electical power. 3. If not draining the tank, reduce tank pressure through the air hose. 4. Drain the tank by slowly opening the drain valve (fig 8.1). Place a catch basin under the valve to protect the surface from water damage.
Silent Air Series Troubleshooting Always inspect the compressor before use, and make sure it is in good working condition. Make sure all air vents are clear. Check the power cable to make sure it is intact and free from cracks, bare wires etc. Avoid using solvents when cleaning plastic parts, most plastics are susceptible to damage from the various types of commercial solvents. Trouble Compressor will not start Possible Cause Corrective Action 1. Blown fuse or circuit breaker tripped 1.
HULK Power Air Compressors Parts List No. Description Qty. No. Description Qty.
Silent Air Series Schematic Drawing 13 HP15P005SS man v.
HULK Power Air Compressors Warranty Statement HULK makes every effort to ensure that this product meets high quality and durability standards. HULK warrants to the original retail consumer a 2-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials. Warranty does not apply to defects due directly or indirectly to misuse, abuse, negligence or accidents, repairs or alterations and lack of maintenance.