User Guide

REMOVING THE FOOT AND CALF MASSAGER
1. Lift the foot and calf massager up, then place a box or other sturdy object beneath it
for support.
2. Locate the air pump on the bottom of the chair, then remove the six sets of screws/washers
that secure the pump to the chair (Fig. 1).
3. Locate the connector box on the bottom left side of the chair, near the foot and calf
massager (Fig.2).
4. Using a Phillips-head screwdriver, remove the two screws that secure the connector box cover,
remove the cover, then disconnect the red connector.
5. Cut any zip ties that secure the cable that runs from the connector box to the foot and calf
massager, to free the cable from the chair base.
6. Remove the box or other sturdy object that is supporting the foot and calf massager,
allowing the massager to drop down to a vertical position.
7. Standing in front of the foot and calf massager, detach the upholstered flap that covers the
massager frame (Fig.3).
NOTE: It is helpful to flip the upholstered flap up onto the seat cushion and place an object on
top of it to hold it out of the way.
Tools Required: Nail clipper or other instrument suitable for cutting zip ties, Phillips-head screwdriver, flat-head
screwdriver, vice grip, small hammer.
NOTE: SAVE ALL SCREWS FOR USE DURING REASSEMBLY.
REPLACING THE FOOT AND CALF MASSAGER
HT-7120
March 14, 2012
(Fig.3)
(Fig.2)
1
Screw/washer
Air pump
(Fig.1)
To ensure that Human Touch
®
products are repaired in a manner that is fully consistent with the practices used during the manufacturing process, Human Touch requires that all
product repairs are performed using only factory-new parts and in accordance with these product repair instructions.
SERVICE LEVEL: 3