Hardware Bag Components: Hex Head Bolt (2) • Hex Locknut (4) • Flat Washer (6) • Cap (4) • Screw (20)
Rev. 6-26-06
1.
Assemble the Cross Tube
Fixed Width Models
Slide cross tube over square
mounting stud on R.H. Assembly
.
Insert (2) hex bolts with (2) flat
washers through cross tube and
stud. Assemble (2) flat washers
and (2) hex locknuts. Tighten
fasteners to 200 in-lbs or until tube
is flattened against mounting stud.
Note: Improper tightening of hard-
ware may result in excess key-
board movement. Install opposite
end of cross tube over (2) studs on
L.H. Assembly and fasten with (2)
flat washers and (2) hex locknuts.
DO NOT TIGHTEN AT THIS TIME!
Adjustable Width Models
Follow same procedure used for
mounting fixed width R.H. & L.H.
Arm assemblies except as follows:
T
o adjust for desir
ed width -
remove & save hardware used to
position two cross halves for ship-
ping. Slide assembly either in or
out to final width and replace hard-
war
e. Tighten hardware between
tube halves to 200 in-lbs. or until
play between tubes is removed.
2.
Install Brackets to Table
Attach assembled Ergo Lift brack-
ets to underside of fr
ont and rear
work surfaces. Attach release lever
to underside of front work surface
with (4) scr
ews provided.
3. Level Keyboard (if necessary)
Left side of tube is designed to
provide leveling capability.
A. Activate release lever so front
surface right hand side is approxi-
mately level with rear surface.
Release lever.
B. Manually raise the left hand
side of front work surface approxi-
mately 1/2” above the right hand
side, hold in this position and tight-
en (2) nuts to 200 in-lbs.
C.
Re-adjust if not level. (Use
dimension less then 1/2” if left
hand side is too high.)
D. Install caps over hex nuts.
4.
Adjust Cables
(if necessar
y)
Cable is pre-set at factory.
Adjustment should only be made if
r
elease lever does not lock key-
board in position (Cable to tight) or
if lever does not release keyboard.
(Cable to loose)
A. To adjust the cable free play,
remove the cable mount from the
cable bracket by removing screw.
B. Loosen the cable hex nut.
C. Adjust the position of the cable
mount by screwing on or off the
desired amount.
D. Tighten the cable hex nut.
E. Make sure the cable end is
installed in the release lever.
Reinstall the cable mount onto the
handle assembly.
5. Tilt Tension (if necessary)
Tilt tension nut is pre-set at the fac-
tory, but can be adjusted by tight-
ening or loosening the hex locknut
as shown.
Lift
.38
Cable Mount
Hex Nut
Washer
Screw