User Manual

C. No Access Under Mounting Location
Use the following instructions to deck mount the Sensor and route the cable to
the side if there is not space for a cable underneath the mounting location.
1. Secure the NMEA pigtail with electrical tape.
NOTE: Unless it is needed, leave the NMEA pigtail
secured to the cable. If you are connecting the pigtail
to a NMEA 0183 device, see Section 3: Connect to
the Control Head for connection information.
2. Route the cable from the Sensor to the
Control head.
The Sensor has two wire routing
notches. Use the cable notch closest to
the intended cable route.
If holes are required to route the cable,
they must be 3/4” (19mm) to allow for
the cable connector.
To use extension cables, see the details
in Section 1: Choose the Mounting
Location.
Taping the NMEA Pigtail
to the Cable
NMEA
Pigtail
Cable
Taped
NMEA Pigtail Cable Out
NOTE: It is important to review the mounting considerations and test run the
cable route as indicated in Section 1 before proceeding with the installation.
10
Installation - NO Access Under