User Guide

26
3. After your selection is made, wait 5 seconds for the unit to return to normal operation. The
selected Units icon should now be visible.
KEEL OFFSET
The Keel Offset function adjusts the digital depth readout to display depth readings from either
the waterline or the keel (lowest point of the boat), instead of from the location of the transducer
(which is usually somewhere in between). This function lets you display transducer location and
depth readouts suited to your needs.
1. To determine the value to enter into the Keel Offset setting, first decide whether depth
from the waterline or depth from the keel is desired. Measurements will need to be made
for the location desired.
2a. For depth from the keel of the boat, accurately measure the vertical distance between the
face of the transducer and the keel of the boat. You will then need to enter this
measurement into the Keel Offset function as a negative (-) number.
Or…
2b. For depth measurements from the waterline, accurately measure the vertical distance
between the face of the transducer and the waterline of the boat. You will then need to
enter this measurement into the Keel Offset function as a positive (+) number.
25
1. While in normal operation mode, press the SET key until the Deep Alarm setting is
displayed and the Deep icon is blinking.
2. Use the UP Arrow key to activate the Deep Alarm and also to increase the selected value.
Use the DOWN Arrow key to reduce the value. Press and hold the UP Arrow key until you
reach the desired depth setting.
NOTE: The minimum Deep Alarm setting cannot meet or drop below the current Shallow Alarm
setting (see Shallow Alarm section).
3. After your selection is made, wait 5 seconds for the unit to return to normal operation. The
Deep icon should now be visible.
4. If the depth of the water is greater than the selected value, the alarm will sound and the
Deep icon will blink to indicate the alarm state. Pressing any key will mute the alarm;
pressing the SET key will mute the alarm and activate the Deep Alarm function for
additional adjustment. To permanently turn the alarm off, use the DOWN Arrow key to
return the display to Off.
UNITS
The Units control function selects the units of measure for depth readout and alarm functions. The
three settings available are: Feet, Meters or Fathoms.
1. While in normal operation mode, press the SET key until Units is displayed and the Units
icon is blinking.
2. Use either Arrow key to view the unit choices until you reach the desired unit: FT for feet,
M for meters, FA for fathoms.
Units
531440-1_B - HDR610 Manual_Eng.qxd 10/12/2005 11:05 AM Page 26