APPENDIX
---------------------------------------------------------------------------------------------------------------------------
CLEAR MOTOR LIMITS
Clear Upper Limit (with Remote)
1. Wake up the Remote.
2. On the motor, press and hold the push button.
3. On the Remote, verify no Group LEDs are on solid.
4. On the Remote, press and release the UP button.
5. The motor will jog two times after the upper limit is cleared.
6. On the Motor, release the push button.
Clear Lower Limit (with Remote)
1. Wake up the Remote.
2. On the motor, press and hold the push button.
3. On the Remote, verify no Group LEDs are on solid.
4. On the Remote, press and release the DOWN button.
5. The motor will jog two times after the lower limit is cleared.
6. On the Motor, release the push button.
---------------------------------------------------------------------------------------------------------------------------
DISABLE GROUPS
1. On the Remote, press and hold the STOP button until LEDs begin to blink.
2. On the Remote, press the Group button that you wish to disable.
3. On the Motor, press and hold the push button on the Motor head.
4. On the Remote, press and release the CLOSE button.
5. The Motor will jog two times after it receives the Group disable message from the Remote.
6. On the Motor, release the push button.