FACTORY RESET
1. On the Motor, press and hold the push button on the Motor head for approximately 6 seconds.
2. The motor will jog two times after 6 seconds have elapsed.
3. On the Motor, continue to press and hold the push button on the Motor head for another 6
seconds.
4. The motor will jog two times after 12 seconds have elapsed.
5. On the Motor, continue to press and hold the push button on the Motor head for another 6
seconds.
6. The motor will jog 2 times after 18 seconds have elapsed.
7. On the Motor, release the push button.
8. The Motor limits, favorite position, Network_Id, Device_Id, Groups, Approved_Controller_Info
and Scenes have been reset.
---------------------------------------------------------------------------------------------------------------------------
CONTROL THE MOTOR WITH DRY CONTACTS 40mm motor only
1. Short the UP dry contact to COMMON and then release the motor moves in the OPEN
direction.
2. With the motor moving, short the UP dry contact to COMMON and then release. The motor
stops.
3. Short the DOWN dry contact to COMMON and then release the motor moves in the DOWN
direction.
4. With the motor moving, short the DOWN dry contact to COMMON and then release. The
motor stops.
Go to Favorite Position (short all 3 contacts)
1. Simultaneously short UP and DOWN dry contacts to COMMON for more than 1.5 seconds,
then release. The motor goes to the favorite position (if both end limits are set).
---------------------------------------------------------------------------------------------------------------------------
ALTERNATE STOP (short all 3 contacts)