User Manual
21
REFERENCE
MAINTENANCE
Electric Shock Hazard
To prevent serious injury or death:
• BEFORE performing maintenance or service, ALWAYS disconnect the power by turning off the circuit
breaker or breakers to the fan locations and conrm Lockout/Tagout procedures are in place.
• If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device,
such as a tag, to the electrical panel.
• Do not remove covers while power is on.
Blade Cleaning
Depending on the commercial application, dust or other particulates can build up on the fan blades over time. At
least every 12 months, a maintenance person or skilled trade professional should clean the blades using a rag or
sponge and hot water or regular cleaning solutions.
DO NOT use chlorine or any chemicals containing chlorine as they may cause damaged to the blades.
Retention System Check
Each fan is installed with a retention system. Every 12 months, check that the Retention Cable is properly attached
to the building structure. Inspect the visible portions of the Retention Cable for damage, including fraying.
The Retention Cable is an important part of the safety system and protects users in the
unlikely event of a catastrophic situation. It is critical for fan owners to ensure that it is intact and properly secured.
Replacement Parts
Please call 1-844-593-FANS (3267) for replacement parts.
Service
If the fan does not operate properly using the procedures in this manual, follow Lockout/Tagout procedures for your
facility and lockout all power to the unit and contact our Technical Department for further assistance at 1-844-593-
FANS (3267).