www.HunterFan.com Table of Contents Ceiling Bracket 30 inches Downrod Ladder 3 Wiring Operation, Maintenance & Cleaning Light Kit 11 Troubleshooting ? ? ? 16 PA G E 15 PA G E 1 PA G E 12 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company 10 PA G E 9 5 Blades Canopy PA G E 6 4 PÁGINA 2 PA G E 7 feet PA G E Save your receipt for proof of purchase. Mounting Options PA G E To register your fan, please visit: www.HunterFan.
www.HunterFan.com What to Expect with Your Installation 1.888.830.1326 Read and Save These Instructions This product conforms to UL Standard 507. If you are unfamiliar with wiring, use a qualified electrician. WARNINGS w.1 - To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building structure and/or an outlet box marked acceptable for fan support of 70 lbs (31.8 kg) and use the mounting screws provided with the outlet box.
www.HunterFan.com Tools Needed Ladder Screwdrivers Pliers 1.888.830.1326 Wire Strippers 9/64” Drill Bit (optional) Power Drill (optional) If mounting to a support structure, you will also need these tools. 3 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company Do not discard the hardware bags or mix parts from different bags. Make note of the symbol printed on each hardware bag. The symbols can be used to identify the appropriate hardware for each step.
34O CEILING www.HunterFan.com Mounting Options OPTION 1 If you have a flat ceiling: 1. You will need a longer downrod (sold separately). 2. If your ceiling angle is greater than 34°, you will also need an Angled Mounting Kit (sold separately).
www.HunterFan.com Ceiling Bracket 1.888.830.1326 r we o nP r Tu OFF For angled ceilings, point opening toward peak. Use wood screws Use machine screws (included) when securing (provided with outlet to support structure with box) when securing to approved electrical outlet existing ceiling fan-rated box. Drill 9/64” pilot holes outlet box. Make sure in support structure to aid it is securely installed in securing ceiling bracket and is acceptable for fan with hardware found in support of 31.
www.HunterFan.com Option 1 Downrod 1.888.830.
www.HunterFan.com KEEP! (not to scale) 8” & 3/8” 1.888.830.1326 STRIP CUT Downrod (continued) ! KEEP Remove the pre-installed setscrew so that the downrod can be inserted. The wires can be cut, but leave at least 8” extending from the top of the downrod. Hand tighten the downrod (at least 4-5 full turns) until it stops. 8” Tighten the setscrew with pliers. DO NOT HAND TIGHTEN. 3/8” If the setscrew is not tightened securely, the fan may fall.
www.HunterFan.com Downrod (continued) Put the wires and downrod through the canopy. Let the canopy sit loosely on top of the fan. DO NOT PICK THE FAN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. 8 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company 1.888.830.
Wiring OM FR CEILIN www.HunterFan.com Note: To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist clockwise until tight. G OM FR T KE Black FR (Ungrounded) M FA N Blue FRO (Ungrounded) AC Blue ING BR Black CEIL White M Using the orange wire connectors from the hardware bag, connect the black wire (ungrounded) from the ceiling to the black and the blue wires from the fan.
www.HunterFan.com Canopy Screw Holes Position the canopy so that, when lifted into place, the canopy fits into the hanging bracket as shown. Lift the canopy into place so that the screw holes are aligned. Insert the two canopy screws found in the hardware bag. 10 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company 1.888.830.
Blades www.HunterFan.com Insert washers found in the hardware bag into the holes in the blades, then secure each blade to a blade iron with screws found in the hardware bag. Lightly attach the blade irons to the motor with screws found in the hardware bag, then securely tighten after both screws are attached. 11 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company 1.888.830.
Light Kit www.HunterFan.com Partially install two light kit assembly screws, found in the hardware bag, halfway into the motor housing as shown. It does not matter which two screw holes you choose. Align the keyhole slots in the top of the light kit assembly with the partially installed assembly screws. Wrap the keyhole slots around the screws and twist counterclockwise. 12 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company 1.888.830.
www.HunterFan.com Light Kit (continued) Feed the 9-pin plug connector coming from the bottom of the motor housing through the center hole in the light kit assembly. Connect it to the plug connector found in the switch housing area of the light kit assembly. Make sure to line up the colored markings on the connectors. Carefully push all switch housing components into the switch housing, then install the switch housing plate using two light kit assembly screws, found in the hardware bag.
www.HunterFan.com Light Kit (continued) 1.888.830.1326 Tab Notch CONGRA YOU’RETULATIONS! DONE! Lift the globe and align the notches in the globe with the tabs in the light kit. Attach the glass bowl to the light kit by twisting it clockwise until it snaps into place. Remove and discard the plastic connectors from the ends of the short pull chains Connect the appropriate pull chain pendant to each of the short chains coming from the light kit. The fan pull chain controls the speed: from high to off.
Operation, Maintenance, & Cleaning www.HunterFan.com r Tu r we o nP ON Reverse Switch When cleaning the fan, use soft brushes or cloths to prevent scratching. Cleaning products may damage the finishes. 15 M3604-01 • 03/21/16 • © 2016 Hunter Fan Company To switch the direction of air flow, move the reverse switch to the opposite position. You will need to remove the light cage and glass to do so. 1.888.830.
www.HunterFan.com Troubleshooting Fan doesn’t work Excessive wobbling Noisy operation • Make sure power switch is on. • Tighten all of the blade and blade iron screws until they are snug. • Tighten the blade and blade iron screws until they are snug. • Pull the pull chain to make sure it is on. • Push the motor reversing switch firmly left or right to ensure that it is engaged. • Check the circuit breaker to ensure the power is turned on. • Make sure the blades spin freely.