User Guide

40
40
WIRING DIAGRAMS
4-wire Heat/Cool System
5-wire Heat/Cool System
Jumper
Wallplate
Terminals
Fan
Relay
Cool
Contactor
Heat Relay
or Valve
24V Supply
Heat/Cool
Rh
Rc
Y/O
W/B
Y1
G
X
X
System
Selector
STD
HP
No Jumper
Wallplate
Terminals
Fan
Relay
Cool 24V
Supply
Heat Relay
or Valve
Heat 24V
Supply
Rh
Rc
Y/O
W/B
Y1
G
Cool
Contactor
X
System
Selector
STD
HP
X - No Connection
41644_model44360_web.pmd
41
41
Single-stage
Heat Pump
2-wire Heat Only
Jumper
X
OR
Heat
Mode
Cool
Mode
Connect to Proper Reversing
Valve Terminal. See Table A
System
Selector
STD
HP
Wallplate
Terminals
Rh
Y/ O
W/ B
Rc
G
Fan
Relay
Reversing
Valve
Compressor
Contactor
Y1
Heat Pump
24V Supply
Jumper
X
X
X
Wallplate
Terminals
Rh
Rc
Heat 24V or
Millivolt Supply
Heat Relay
or Valve
X
Y/O
W/B
Y1
G
System
Selector
STD
HP
X - No Connection